Grounding Switch JN15 Model 24kV Indoor High Voltage Earthing Switch

Grounding Switch JN15 Model 24kV Indoor High Voltage Earthing Switch

Do Better Performances in Demanding Duties
Yueqing Aiso gain client trust thanks to their proven reputation for reliability, performance and long life. Electrical equipment from Yueqing Aiso are available for original equipment manufacturers (OEM) to incorporate in their own installations or for use in repair, retrofit and upgrade projects.
Why Yueqing AIso?
1,Full engineering and technical support: 3 professional manufacturers, and technical service team.
2,Quality is No1 ,our culture.
3,Quickly lead times:”Time is gold” for you and for us
4,30min fast response:we have professional team,7*20H


Grounding Earthing Switch Product Description

Jn15 indoor high-voltage alternating-current earthing switch is used as a support product for indoor three-phase alternating- current power systems of 3 ~ 40.5kV and 50(60)Hz and high- voltage switch cabinets or as an earthing switch for the overhauls of high-voltage electrical equipment. It is characterized by simple and compact structure, light weight, flexible operation, easy installation and good thermal stability and dynamic stability.

JN15-12/24/40.5KV indoor high-voltage alternating-current earthing switch is produced in line with the following standards and codes. 

GB 1985 High-voltage alternating-current disconnectors and earthing switchesIEC 62271-102 High-voltage alternating-current disconnectors and earthing switches
High Voltage Earthing Switch Environmental Conditions
Ambient temperature: - 40°C~+40°C (below 35°C within 24 hours) Relative humidity: ≤95% (daily average) or ≤90% (monthly average)Altitude:  ≤ 1000m 

Indoor High Voltage Earthing Switch Main Technical Parameters
Item Unit Rsference valie
Rated voltage KV 12/24/40.5
Rated insulation level Lightning impulse withstand voltage KV 75,145,185
1min power-frequency withstand voltage KV 42,65,95
Rated frequency Hz 50 / 60
Rated short-time withstand current kA 31.5 / 40
Rated withstand current(peak value) kA 80 / 100
Interphase center distance mm See the table
 

Note:Please contact the factory to confirm the latest parameters

Outline and installation dimension

Grounding Switch JN15 Model 24kV Indoor High Voltage Earthing Switch

Model and specification E L C
JN15-24/31.5-275 275 810 646

Product picture details  (Real product picture, unprocessed)