New Delivery for Auto Circuit Recloser - ZW7/CT(built-in) 40.5kV Outdoor Transformer Substation Vacuum Circuit Breaker – Aiso

New Delivery for Auto Circuit Recloser - ZW7/CT(built-in) 40.5kV Outdoor Transformer Substation Vacuum Circuit Breaker – Aiso
We continue to keep increasing and perfecting our solutions and service. At the same time, we operate actively to do research and enhancement for Auto Circuit Recloser, 36kv Disconnector Switches, Low Voltage Power Capacitor, We can easily offer you by far the most aggressive prices and good quality, because we've been much additional Specialist! So please will not hesitate to call us.
New Delivery for Auto Circuit Recloser - ZW7/CT(built-in) 40.5kV Outdoor Transformer Substation Vacuum Circuit Breaker – Aiso Detail:

Product Description

ZW7/CT(built-in) 40.5kV Outdoor Transformer Substation Vacuum Circuit Breaker :

Applicable place: (Suitable for frequent operating places)

1.Urban,rural network.

2.Industrial enterprises.

It is mainly used in outdoor 40.5KV distribution system to control and protect.

 

Advantages

1.It conforms to GB1984-89 and IEC56“AC high voltage circuit breaker”.

2.It can be charged and switched by remote control switch or by hand.

3.Good sealing, anti-aging, high pressure, no burning, no explosion, long life, convenient installation and maintenance features.

4.It is composed of spring operating mechanism or electromagnetic operating mechanism.

5.Its overall structure is supported by porcelain insulator, vacuum interrupter built in upper insulator, downside insulator used for supporting. The breaker applies

 

High Voltage Vacuum Circuit Breaker Environmental Conditions 

Ambient temperature:-15°C~+40°C
Relative humidity:≤95%or≤90%

The daily average saturated vapor pressure:≤2.2KPa;

The monthly average value:≤1.8KPa.

Altitude:≤1000m

Seismic intensity:≤8

*No fire, explosion, serious filthy, chemical corrosion and violent vibration of places.

 

ZW7 Vacuum Breaker Main Technical Parameters

Description

Unit

Data

Rated voltage

KV

35/40.5

Rated current

A

630/1250

Rated frequency

Hz

50/60

Rated short-circuit brekaing current

kA

20/25/31.5/40

Meachical life

 Time

10000

Note:Please contact the factory to confirm the latest parameters

Overall and installation dimension

China Wenzhou Outdoor 40.5kV High Voltage Vacuum Circuit Breaker
 

 

 


Product detail pictures:

New Delivery for Auto Circuit Recloser - ZW7/CT(built-in) 40.5kV Outdoor Transformer Substation Vacuum Circuit Breaker – Aiso detail pictures

New Delivery for Auto Circuit Recloser - ZW7/CT(built-in) 40.5kV Outdoor Transformer Substation Vacuum Circuit Breaker – Aiso detail pictures

New Delivery for Auto Circuit Recloser - ZW7/CT(built-in) 40.5kV Outdoor Transformer Substation Vacuum Circuit Breaker – Aiso detail pictures

New Delivery for Auto Circuit Recloser - ZW7/CT(built-in) 40.5kV Outdoor Transformer Substation Vacuum Circuit Breaker – Aiso detail pictures

New Delivery for Auto Circuit Recloser - ZW7/CT(built-in) 40.5kV Outdoor Transformer Substation Vacuum Circuit Breaker – Aiso detail pictures


Related Product Guide:

Our goal is usually to deliver high quality items at aggressive price ranges, and top-notch service to shoppers around the entire world. We're ISO9001, CE, and GS certified and strictly adhere to their high quality specifications for New Delivery for Auto Circuit Recloser - ZW7/CT(built-in) 40.5kV Outdoor Transformer Substation Vacuum Circuit Breaker – Aiso, The product will supply to all over the world, such as: Nepal, Bandung, Gambia, By adhering to the principle of "human oriented, winning by quality", our company sincerely welcomes merchants from at home and abroad to visit us, talk business with us and jointly create a brilliant future.
Leave Your Message
Send Your Inquiry Now