Place of Origin:Zhejiang, ChinaBrand Name: AISO/OEMModel Number: DW45-4000/3PType: Air, FixedPoles Number: 3Product: Vacuum circuit switchProduct name: 4000A air circuit breaker Rated Voltage: 400V/690VRated current: 4000ARated frequency:50HzMaterial: CopperCertificate: ISO9001-2015Customized:Accept special order
Application of Intelligent Air Circuit Breaker(ACB)
DW45 series universal circuit breaker(hereinafter referred to as breaker)is suitablefor the circuit of AC 50Hz with rated voltage 400V, 690V and rated current up to 6300A.It is mainly used to distribute electric energy and protect circuits and power-supplyequipment from overload, under-voltage, short-circuit and single-phase earthing. withintelligentized and selective protection functions, the breaker can improve the reliabilityof power supply, and avoid unnecessary power failure. The breaker is applicable forpower stations, factories, mines(for 690V) and modern high-buildings, especially for thedistribution system of intelligentized building. This breaker conforms to IEC60947-2 andGB14048.2. The whole series have past CCC certifi cation.
Feature of Intelligent Air Circuit Breaker(ACB)
1. Rated AC current: 630A-6300A
2. Short-circuit breaking capacity: 80KA-120KA
3. Rated Voltage: under AC690V
4. Two Types: draw-out type and fixed type
5. Equipped with many types of intelligent controllers, of different functions.
6. Both the 3 Pole and 4 Pole air circuit breakers are available.
7. Standards: IEC60947-2, GB14048.2
Categories of Intelligent Air Circuit Breaker(ACB)
1. Our air circuit breaker can be of two installation types: fixed type and draw-out type
2. Number of poles: 3 pole and 4 pole
3. Operation type: manual operation, auto operation
4. Trip types: Intelligent controller, under voltage instant ( or time delay type) trip and shunt trip
5. Intelligent controller categories: L type(basic type), M type( Standard type), and H type ( communication type)
Main Technical Parameters
Framesize rated current inm(A) |
Rated current InA |
Rated insulation voltage(v) |
Ratedlimit short-circuitbreaking capacity lcu(kA) |
Ratedoperating short-circuitbreaking capacity lcu(kA) |
Rated short-time withstand current lcw kA(1s) |
||
400v | 690v | 400v | 690v | ||||
2000 | 630 | 690 | 80 | 50 | 50 | 40 | 50 |
800 | |||||||
1000 | |||||||
1250 | |||||||
1600 | |||||||
2000 | |||||||
3200 | 2000 | 100 | 65 | 65 | 50 | 65 | |
2500 | |||||||
4000 | 3200 | 100 | 65 | 65 | 50 | 65/80 | |
3600 | |||||||
4000 | |||||||
6300 | 4000 | 120 | 80 | 80 | 70 | 85/100 | |
5000 | |||||||
6300 |