Yueqing Manufacturer Good Quality 11Kv/12kV Vacuum Circuit Breaker

Short Description:

Specification:900-1000 USD/PIECEUse Parts:1 PIECESupply Ability:100 PIECEPayment Terms:TT , LC , Others Tags:


Product Detail

Product Tags

Place of OriginZhejiang, ChinaBrand NameAISO/OEMModel NumberZW32-12GTypeVacuum, OutdoorPoles Number3Product11kV/12kV vacuum circuit breakerRated Voltage11kV/12KVRated current630A,1250ARated frequency50HzMechanical life10000TimesUsesHigh voltageWeightAbout110KgCustomizedAccept special orderPackaging DetailsStandard export wooden case packingPortNingbo or Shanghai

fastest growing factory 12kv vacuum circuit breaker

22

ZW32-12 type miniaturization of outdoor high vacuum circuit breaker (hereinafter referred to as the circuit breaker) is three-phase ac frequency 50Hz, rated voltage of 7.2-12kV outdoor high voltage switch equipment . Circuit breaker meet the national GB1984 the high-voltage ac breaker and professional standard JB3855 “3.6~40.5 kV voltage vacuum circuit breaker outdoor exchange” and relevant IEC standard. For industrial enterprise, power plants and substation of electrical equipment for control and protection with, and rural power grid frequent operation place.Circuit breaker has repeatedly open circuit and fast reclose ability.

Model description

444

Environmental conditions

1,Environmental temperature: no high than 40℃, no less than -40℃.

2,Air relative humidity: day average no greater than 95%, on average less than 90%.

3,The altitude does not exceed 2000m.

4,Wind pressure not more than 700Pa(equivalent to wind speed 34m/s)

5,Seismic intensity not more than eight level.

6,No fire, explosion, serious filthy, chemical corrosion and violent vibration of places.

7,If the customers have other special requirements, can be in order to put forward , our company can offer most satisfied.

Technical parameters

Item Description Unit Data
1 Ratedvoltage KV 12
2 Ratedinsulationlevel 1minwithstandvoltage Dry KV 42
Wet 34
Lightningimpulsewithstandvoltage(peak) 75
3 Ratedcurrent A 630400200
4 Ratedbreakcurrentonshorting KA 201612.5
5 Ratedoperatingsequence OC-0.3s-CO-180S-CO
6 Opencircuittimesofratedshortdropoutcurrent Times 30
7 Ratedshortcircuitmakingcurrent KA 50
8 Ratedpeakwithstandcurrent
9 Ratedshortingwithstandcurrent KA 20
10 Rateddurationofshort-circuit S 4
11 Openingtime(shunttrip) Maxoperatingvoltage ms 15~50
Ratedoperatingvoltage
Min.operatingvoltage 30~60
12 Closingtime ms 25~50
13 Totalbreakingtime ≤100
14 Arcingtime ≤20
15 Mechanicallife Times 10,000
16 Ratedinputpowerofenergystorgemotor W 40
17 Ratedoperatingvoltageandsecondarycircuitratedvoltage V DC22011024
AC22011024
18 EnergystoragetomeUnderratedvoltage S ≤10
19 Over-currentrelease Ratedcurrent A 5
Theaccuracygradeoftrippingcurrent % ±10

Outline and installation dimension

66

55

 

Product details

55 (2)